Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Med Sci Monit ; 29: e939949, 2023 May 15.
Article in English | MEDLINE | ID: covidwho-2320022

ABSTRACT

BACKGROUND Self-injection locking (SIL) radar uses continuous-wave radar and an injection-locked oscillator-based frequency discriminator that receives and demodulates radar signals remotely to monitor vital signs. This study aimed to compare SIL radar with traditional electrocardiogram (ECG) measurements to monitor respiratory rate (RR) and heartbeat rate (HR) during the COVID-19 pandemic at a single hospital in Taiwan. MATERIAL AND METHODS We recruited 31 hospital staff members (16 males and 15 females) for respiratory rates (RR) and heartbeat rates (HR) detection. Data acquisition with the SIL radar and traditional ECG was performed simultaneously, and the accuracy of the measurements was evaluated using Bland-Altman analysis. RESULTS To analyze the results, participates were divided into 2 groups (individual subject and multiple subjects) by gender (male and female), or 4 groups (underweight, normal weight, overweight, and obesity) by body mass index (BMI). The results were analyzed using mean bias errors (MBE) and limits of agreement (LOA) with a 95% confidence interval. Bland-Altman plots were utilized to illustrate the difference between the SIL radar and ECG monitor. In all BMI groups, results of RR were more accurate than HR, with a smaller MBE. Furthermore, RR and HR measurements of the male groups were more accurate than those of the female groups. CONCLUSIONS We demonstrated that non-contact SIL radar could be used to accurately measure HR and RR for hospital healthcare during the COVID-19 pandemic.


Subject(s)
COVID-19 , Signal Processing, Computer-Assisted , Male , Humans , Female , Radar , Taiwan/epidemiology , Pandemics , Vital Signs , Heart Rate , Respiratory Rate , Hospitals , Algorithms , Monitoring, Physiologic/methods
2.
Sensors (Basel) ; 23(8)2023 Apr 07.
Article in English | MEDLINE | ID: covidwho-2306248

ABSTRACT

Frequency estimation plays a critical role in vital sign monitoring. Methods based on Fourier transform and eigen-analysis are commonly adopted techniques for frequency estimation. Because of the nonstationary and time-varying characteristics of physiological processes, time-frequency analysis (TFA) is a feasible way to perform biomedical signal analysis. Among miscellaneous approaches, Hilbert-Huang transform (HHT) has been demonstrated to be a potential tool in biomedical applications. However, the problems of mode mixing, unnecessary redundant decomposition and boundary effect are the common deficits that occur during the procedure of empirical mode decomposition (EMD) or ensemble empirical mode decomposition (EEMD). The Gaussian average filtering decomposition (GAFD) technique has been shown to be appropriate in several biomedical scenarios and can be an alternative to EMD and EEMD. This research proposes the combination of GAFD and Hilbert transform that is termed the Hilbert-Gauss transform (HGT) to overcome the conventional drawbacks of HHT in TFA and frequency estimation. This new method is verified to be effective for the estimation of respiratory rate (RR) in finger photoplethysmography (PPG), wrist PPG and seismocardiogram (SCG). Compared with the ground truth values, the estimated RRs are evaluated to be of excellent reliability by intraclass correlation coefficient (ICC) and to be of high agreement by Bland-Altman analysis.


Subject(s)
Algorithms , Respiratory Rate , Reproducibility of Results , Photoplethysmography/methods , Normal Distribution , Signal Processing, Computer-Assisted
3.
Sensors (Basel) ; 23(5)2023 Feb 25.
Article in English | MEDLINE | ID: covidwho-2269584

ABSTRACT

The early identification of microvascular changes in patients with Coronavirus Disease 2019 (COVID-19) may offer an important clinical opportunity. This study aimed to define a method, based on deep learning approaches, for the identification of COVID-19 patients from the analysis of the raw PPG signal, acquired with a pulse oximeter. To develop the method, we acquired the PPG signal of 93 COVID-19 patients and 90 healthy control subjects using a finger pulse oximeter. To select the good quality portions of the signal, we developed a template-matching method that excludes samples corrupted by noise or motion artefacts. These samples were subsequently used to develop a custom convolutional neural network model. The model accepts PPG signal segments as input and performs a binary classification between COVID-19 and control samples. The proposed model showed good performance in identifying COVID-19 patients, achieving 83.86% accuracy and 84.30% sensitivity (hold-out validation) on test data. The obtained results indicate that photoplethysmography may be a useful tool for microcirculation assessment and early recognition of SARS-CoV-2-induced microvascular changes. In addition, such a noninvasive and low-cost method is well suited for the development of a user-friendly system, potentially applicable even in resource-limited healthcare settings.


Subject(s)
COVID-19 , Photoplethysmography , Humans , Photoplethysmography/methods , SARS-CoV-2 , Oximetry/methods , Oxygen , Neural Networks, Computer , Signal Processing, Computer-Assisted , Heart Rate
4.
Biosensors (Basel) ; 13(1)2022 Dec 22.
Article in English | MEDLINE | ID: covidwho-2227523

ABSTRACT

Occupational stress is a major challenge in modern societies, related with many health and economic implications. Its automatic detection in an office environment can be a key factor toward effective management, especially in the post-COVID era of changing working norms. The aim of this study is the design, development and validation of a multisensor system embedded in a computer mouse for the detection of office work stress. An experiment is described where photoplethysmography (PPG) and galvanic skin response (GSR) signals of 32 subjects were obtained during the execution of stress-inducing tasks that sought to simulate the stressors present in a computer-based office environment. Kalman and moving average filters were used to process the signals and appropriately formulated algorithms were applied to extract the features of pulse rate and skin conductance. The results found that the stressful periods of the experiment significantly increased the participants' reported stress levels while negatively affecting their cognitive performance. Statistical analysis showed that, in most cases, there was a highly significant statistical difference in the physiological parameters measured during the different periods of the experiment, without and with the presence of stressors. These results indicate that the proposed device can be part of an unobtrusive system for monitoring and detecting the stress levels of office workers.


Subject(s)
COVID-19 , Occupational Stress , Humans , Computers , Heart Rate/physiology , Algorithms , Photoplethysmography , Signal Processing, Computer-Assisted
5.
PLoS One ; 17(11): e0277081, 2022.
Article in English | MEDLINE | ID: covidwho-2109327

ABSTRACT

The COVID-19 pandemic has exposed the vulnerability of healthcare services worldwide, raising the need to develop novel tools to provide rapid and cost-effective screening and diagnosis. Clinical reports indicated that COVID-19 infection may cause cardiac injury, and electrocardiograms (ECG) may serve as a diagnostic biomarker for COVID-19. This study aims to utilize ECG signals to detect COVID-19 automatically. We propose a novel method to extract ECG signals from ECG paper records, which are then fed into one-dimensional convolution neural network (1D-CNN) to learn and diagnose the disease. To evaluate the quality of digitized signals, R peaks in the paper-based ECG images are labeled. Afterward, RR intervals calculated from each image are compared to RR intervals of the corresponding digitized signal. Experiments on the COVID-19 ECG images dataset demonstrate that the proposed digitization method is able to capture correctly the original signals, with a mean absolute error of 28.11 ms. The 1D-CNN model (SEResNet18), which is trained on the digitized ECG signals, allows to identify between individuals with COVID-19 and other subjects accurately, with classification accuracies of 98.42% and 98.50% for classifying COVID-19 vs. Normal and COVID-19 vs. other classes, respectively. Furthermore, the proposed method also achieves a high-level of performance for the multi-classification task. Our findings indicate that a deep learning system trained on digitized ECG signals can serve as a potential tool for diagnosing COVID-19.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , Signal Processing, Computer-Assisted , Pandemics , Algorithms , Neural Networks, Computer , Electrocardiography
6.
Med Eng Phys ; 109: 103904, 2022 11.
Article in English | MEDLINE | ID: covidwho-2061652

ABSTRACT

OBJECTIVE: Coronavirus disease 2019 (COVID-19) targets several tissues of the human body; among these, a serious impact has been observed in the microvascular system. The aim of this study was to verify the presence of photoplethysmographic (PPG) signal modifications in patients affected by COVID-19 at different levels of severity. APPROACH: The photoplethysmographic signal was evaluated in 93 patients with COVID-19 of different severity (46: grade 1; 47: grade 2) and in 50 healthy control subjects. A pre-processing step removes the long-term trend and segments of each pulsation in the input signal. Each pulse is approximated with a model generated from a multi-exponential curve, and a Least Squares fitting algorithm determines the optimal model parameters. Using the parameters of the mathematical model, three different classifiers (Bayesian, SVM and KNN) were trained and tested to discriminate among healthy controls and patients with COVID, stratified according to the severity of the disease. Results are validated with the leave-one-subject-out validation method. MAIN RESULTS: Results indicate that the fitting procedure obtains a very high determination coefficient (above 99% in both controls and pathological subjects). The proposed Bayesian classifier obtains promising results, given the size of the dataset, and variable depending on the classification strategy. The optimal classification strategy corresponds to 79% of accuracy, with 90% of specificity and 67% of sensibility. SIGNIFICANCE: The proposed approach opens the possibility of introducing a low cost and non-invasive screening procedure for the fast detection of COVID-19 disease, as well as a promising monitoring tool for hospitalized patients, with the purpose of stratifying the severity of the disease.


Subject(s)
COVID-19 , Photoplethysmography , Humans , Photoplethysmography/methods , COVID-19/diagnosis , Signal Processing, Computer-Assisted , Bayes Theorem , Heart Rate , Algorithms
7.
Sensors (Basel) ; 22(16)2022 Aug 16.
Article in English | MEDLINE | ID: covidwho-2024041

ABSTRACT

With the vigorous development of ubiquitous sensing technology, an increasing number of scholars pay attention to non-contact vital signs (e.g., Respiration Rate (RR) and Heart Rate (HR)) detection for physical health. Since Impulse Radio Ultra-Wide Band (IR-UWB) technology has good characteristics, such as non-invasive, high penetration, accurate ranging, low power, and low cost, it makes the technology more suitable for non-contact vital signs detection. Therefore, a non-contact multi-human vital signs detection method based on IR-UWB radar is proposed in this paper. By using this technique, the realm of multi-target detection is opened up to even more targets for subjects than the more conventional single target. We used an optimized algorithm CIR-SS based on the channel impulse response (CIR) smoothing spline method to solve the problem that existing algorithms cannot effectively separate and extract respiratory and heartbeat signals. Also in our study, the effectiveness of the algorithm was analyzed using the Bland-Altman consistency analysis statistical method with the algorithm's respiratory and heart rate estimation errors of 5.14% and 4.87%, respectively, indicating a high accuracy and precision. The experimental results showed that our proposed method provides a highly accurate, easy-to-implement, and highly robust solution in the field of non-contact multi-person vital signs detection.


Subject(s)
Radar , Signal Processing, Computer-Assisted , Algorithms , Heart Rate , Humans , Respiratory Rate , Vital Signs
8.
Sci Rep ; 12(1): 14412, 2022 08 24.
Article in English | MEDLINE | ID: covidwho-2016837

ABSTRACT

This paper describes a novel way to measure, process, analyze, and compare respiratory signals acquired by two types of devices: a wearable sensorized belt and a microwave radar-based sensor. Both devices provide breathing rate readouts. First, the background research is presented. Then, the underlying principles and working parameters of the microwave radar-based sensor, a contactless device for monitoring breathing, are described. The breathing rate measurement protocol is then presented, and the proposed algorithm for octave error elimination is introduced. Details are provided about the data processing phase; specifically, the management of signals acquired from two devices with different working principles and how they are resampled with a common processing sample rate. This is followed by an analysis of respiratory signals experimentally acquired by the belt and microwave radar-based sensors. The analysis outcomes were checked using Levene's test, the Kruskal-Wallis test, and Dunn's post hoc test. The findings show that the proposed assessment method is statistically stable. The source of variability lies in the person-triggered breathing patterns rather than the working principles of the devices used. Finally, conclusions are derived, and future work is outlined.


Subject(s)
Microwaves , Radar , Algorithms , Humans , Monitoring, Physiologic/methods , Respiration , Respiratory Rate , Signal Processing, Computer-Assisted
9.
Proc Inst Mech Eng H ; 236(9): 1430-1448, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-1956987

ABSTRACT

Incidence and exacerbation of some of the cardiovascular diseases in the presence of the coronavirus will lead to an increase in the mortality rate among patients. Therefore, early diagnosis of such diseases is critical, especially during the COVID-19 pandemic (mild COVID-19 infection). Thus, for diagnosing the heart diseases related to the COVID-19, an automatic, non-invasive, and inexpensive method based on the heart sound processing approach is proposed. In the present study, a set of features related to the nature of heart signals is defined and extracted. The investigated features included morphological and statistical features in the heart sound frequencies. By extracting and selecting a set of effective features related to the mentioned diseases, and avoiding to use different segmentation and filtering techniques, dependence on a limited dataset and specific sampling procedures has been eliminated. Different classifiers with various kernels are applied for diagnosis in data unbalanced and balanced conditions. The results showed 93.15% accuracy and 93.72% F1-score using 60 effective features in data balanced conditions. The identification system using the extracted features from Azad dataset is able to achieve the desired results in a generalized dataset. In this way, in the shortest possible sampling time, the present system provided an effective and generalizable method and a practical model for diagnosing important cardiovascular diseases in the presence of coronavirus in the COVID-19 pandemic.


Subject(s)
COVID-19 , Cardiovascular Diseases , Heart Sounds , COVID-19/diagnosis , COVID-19 Testing , Cardiovascular Diseases/diagnosis , Humans , Pandemics , Phonocardiography/methods , Signal Processing, Computer-Assisted
10.
IEEE Trans Biomed Circuits Syst ; 16(4): 664-678, 2022 08.
Article in English | MEDLINE | ID: covidwho-1948843

ABSTRACT

A respiratory disorder that attacks COVID-19 patients requires intensive supervision of medical practitioners during the isolation period. A non-contact monitoring device will be a suitable solution for reducing the spread risk of the virus while monitoring the COVID-19 patient. This study uses Frequency-Modulated Continuous Wave (FMCW) radar and Machine Learning (ML) to obtain respiratory information and analyze respiratory signals, respectively. Multiple subjects in a room can be detected simultaneously by calculating the Angle of Arrival (AoA) of the received signal and utilizing the Multiple Input Multiple Output (MIMO) of FMCW radar. Fast Fourier Transform (FFT) and some signal processing are implemented to obtain a breathing waveform. ML helps the system to analyze the respiratory signals automatically. This paper also compares the performance of several ML algorithms such as Multinomial Logistic Regression (MLR), Decision Tree (DT), Random Forest (RF), Support Vector Machine (SVM), eXtreme Gradient Boosting (XGB), Light Gradient Boosting Machine (LGBM), CatBoosting (CB) Classifier, Multilayer Perceptron (MLP), and three proposed stacked ensemble models, namely Stacked Ensemble Classifier (SEC), Boosting Tree-based Stacked Classifier (BTSC), and Neural Stacked Ensemble Model (NSEM) to obtain the best ML model. The results show that the NSEM algorithm achieves the best performance with 97.1% accuracy. In the real-time implementation, the system could simultaneously detect several objects with different breathing characteristics and classify the respiratory signals into five different classes.


Subject(s)
COVID-19 , Radar , Algorithms , Humans , Machine Learning , Respiration , Signal Processing, Computer-Assisted
11.
Sensors (Basel) ; 22(13)2022 Jun 27.
Article in English | MEDLINE | ID: covidwho-1911522

ABSTRACT

The recent SARS-CoV2 pandemic has put a great challenge on university courses. Electronics teaching requires real laboratory experiences for students, which cannot be realized if access to physical infrastructures is prohibited. A possible solution would be to distribute to students, at home, electronics equipment suitable for laboratory experiments, but no reasonable product is currently available off-the-shelf. In this paper, the design and development of a very-low-cost experimental board tailored to these needs is presented. It contains both programmable prototyping circuitry based on a microcontroller and an FPGA and a set of measurement instruments, similar to the ones found on a typical lab desk, such as a digital storage oscilloscope, multimeter, analog signal generator, logic state analyzer and digital pattern generator. A first board, suitable for analog and digital electronics experiments, has been designed and manufactured, and is described in this paper. The board has been successfully used in master's degrees and PhD courses.


Subject(s)
COVID-19 , Signal Processing, Computer-Assisted , Electronics , Equipment Design , Humans , RNA, Viral , SARS-CoV-2
12.
IEEE J Biomed Health Inform ; 26(6): 2481-2492, 2022 06.
Article in English | MEDLINE | ID: covidwho-1878964

ABSTRACT

OBJECTIVE: At-home monitoring of respiration is of critical urgency especially in the era of the global pandemic due to COVID-19. Electrocardiogram (ECG) and seismocardiogram (SCG) signals-measured in less cumbersome contact form factors than the conventional sealed mask that measures respiratory air flow-are promising solutions for respiratory monitoring. In particular, respiratory rates (RR) can be estimated from ECG-derived respiratory (EDR) and SCG-derived respiratory (SDR) signals. Yet, non-respiratory artifacts might still be present in these surrogates of respiratory signals, hindering the accuracy of the RRs estimated. METHODS: In this paper, we propose a novel U-Net-based cascaded framework to address this problem. The EDR and SDR signals were transformed to the spectro-temporal domain and subsequently denoised by a 2D U-Net to reduce the non-respiratory artifacts. MAJOR RESULTS: We have shown that the U-Net that fused an EDR input and an SDR input achieved a low mean absolute error of 0.82 breaths per minute (bpm) and a coefficient of determination (R2) of 0.89 using data collected from our chest-worn wearable patch. We also qualitatively provided insights on the complementariness between EDR and SDR signals and demonstrated the generalizability of the proposed framework. CONCLUSION: ECG and SCG collected from a chest-worn wearable patch can complement each other and yield reliable RR estimation using the proposed cascaded framework. SIGNIFICANCE: We anticipate that convenient and comfortable ECG and SCG measurement systems can be augmented with this framework to facilitate pervasive and accurate RR measurement.


Subject(s)
COVID-19 , Respiratory Rate , Artifacts , Electrocardiography , Humans , Respiration , Signal Processing, Computer-Assisted
13.
Comput Biol Med ; 146: 105540, 2022 07.
Article in English | MEDLINE | ID: covidwho-1814280

ABSTRACT

OBJECTIVE: Studies showed that many COVID-19 survivors develop sub-clinical to clinical heart damage, even if subjects did not have underlying heart disease before COVID. Since Electrocardiogram (ECG) is a reliable technique for cardiovascular disease diagnosis, this study analyzes the 12-lead ECG recordings of healthy and post-COVID (COVID-recovered) subjects to ascertain ECG changes after suffering from COVID-19. METHOD: We propose a shallow 1-D convolutional neural network (CNN) deep learning architecture, namely ECG-iCOVIDNet, to distinguish ECG data of post-COVID subjects and healthy subjects. Further, we employed ShAP technique to interpret ECG segments that are highlighted by the CNN model for the classification of ECG recordings into healthy and post-COVID subjects. RESULTS: ECG data of 427 healthy and 105 post-COVID subjects were analyzed. Results show that the proposed ECG-iCOVIDNet model could classify the ECG recordings of healthy and post-COVID subjects better than the state-of-the-art deep learning models. The proposed model yields an F1-score of 100%. CONCLUSION: So far, we have not come across any other study with an in-depth ECG signal analysis of the COVID-recovered subjects. In this study, it is shown that the shallow ECG-iCOVIDNet CNN model performed good for distinguishing ECG signals of COVID-recovered subjects from those of healthy subjects. In line with the literature, this study confirms changes in the ECG signals of COVID-recovered patients that could be captured by the proposed CNN model. Successful deployment of such systems can help the doctors identify the changes in the ECG of the post-COVID subjects on time that can save many lives.


Subject(s)
COVID-19 , Signal Processing, Computer-Assisted , Electrocardiography/methods , Humans , Neural Networks, Computer
14.
Sensors (Basel) ; 22(7)2022 Apr 05.
Article in English | MEDLINE | ID: covidwho-1785899

ABSTRACT

Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i.e., in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed extended Kalman filter (EKF) based algorithm.


Subject(s)
Mothers , Signal Processing, Computer-Assisted , Algorithms , Arrhythmias, Cardiac , Electrocardiography/methods , Female , Fetal Monitoring/methods , Fetus , Humans , Pilot Projects , Pregnancy
15.
Sensors (Basel) ; 22(7)2022 Mar 25.
Article in English | MEDLINE | ID: covidwho-1785895

ABSTRACT

Heart rate (HR) and respiratory rate (fR) can be estimated by processing videos framing the upper body and face regions without any physical contact with the subject. This paper proposed a technique for continuously monitoring HR and fR via a multi-ROI approach based on the spectral analysis of RGB video frames recorded with a mobile device (i.e., a smartphone's camera). The respiratory signal was estimated by the motion of the chest, whereas the cardiac signal was retrieved from the pulsatile activity at the level of right and left cheeks and forehead. Videos were recorded from 18 healthy volunteers in four sessions with different user-camera distances (i.e., 0.5 m and 1.0 m) and illumination conditions (i.e., natural and artificial light). For HR estimation, three approaches were investigated based on single or multi-ROI approaches. A commercially available multiparametric device was used to record reference respiratory signals and electrocardiogram (ECG). The results demonstrated that the multi-ROI approach outperforms the single-ROI approach providing temporal trends of both the vital parameters comparable to those provided by the reference, with a mean absolute error (MAE) consistently below 1 breaths·min-1 for fR in all the scenarios, and a MAE between 0.7 bpm and 6 bpm for HR estimation, whose values increase at higher distances.


Subject(s)
Electrocardiography , Respiratory Rate , Computers, Handheld , Heart Rate , Humans , Monitoring, Physiologic , Respiratory Rate/physiology , Signal Processing, Computer-Assisted
16.
Comput Biol Med ; 145: 105491, 2022 06.
Article in English | MEDLINE | ID: covidwho-1773224

ABSTRACT

The paper proposes a graph-theoretical approach to auscultation, bringing out the potential of graph features in classifying the bioacoustics signals. The complex network analysis of the bioacoustics signals - vesicular (VE) and bronchial (BR) breath sound - of 48 healthy persons are carried out for understanding the airflow dynamics during respiration. The VE and BR are classified by the machine learning techniques extracting the graph features - the number of edges (E), graph density (D), transitivity (T), degree centrality (Dcg) and eigenvector centrality (Ecg). The higher value of E, D, and T in BR indicates the temporally correlated airflow through the wider tracheobronchial tract resulting in sustained high-intense low-frequencies. The frequency spread and high-frequencies in VE, arising due to the less correlated airflow through the narrow segmental bronchi and lobar, appears as a lower value for E, D, and T. The lower values of Dcg and Ecg justify the inferences from the spectral and other graph parameters. The study proposes a methodology in remote auscultation that can be employed in the current scenario of COVID-19.


Subject(s)
COVID-19 , Signal Processing, Computer-Assisted , Auscultation , Humans , Lung , Machine Learning
17.
Sensors (Basel) ; 22(6)2022 Mar 11.
Article in English | MEDLINE | ID: covidwho-1765832

ABSTRACT

Wearable sensors are becoming very popular recently due to their ease of use and flexibility in recording data from home [...].


Subject(s)
Wearable Electronic Devices , Signal Processing, Computer-Assisted
18.
Sensors (Basel) ; 22(5)2022 Feb 24.
Article in English | MEDLINE | ID: covidwho-1715644

ABSTRACT

The importance of an embedded wearable device with automatic detection and alarming cannot be overstated, given that 15-30% of patients with atrial fibrillation are reported to be asymptomatic. These asymptomatic patients do not seek medical care, hence traditional diagnostic tools including Holter are not effective for the further prevention of associated stroke or heart failure. This is likely to be more so in the era of COVID-19, in which patients become more reluctant on hospitalization and checkups. However, little literature is available on this important topic. For this reason, this study developed efficient deep learning with model compression, which is designed to use ECG data and classify arrhythmia in an embedded wearable device. ECG-signal data came from Korea University Anam Hospital in Seoul, Korea, with 28,308 unique patients (15,412 normal and 12,896 arrhythmia). Resnets and Mobilenets with model compression (TensorFlow Lite) were applied and compared for the diagnosis of arrhythmia in an embedded wearable device. The weight size of the compressed model registered a remarkable decrease from 743 MB to 76 KB (1/10000), whereas its performance was almost the same as its original counterpart. Resnet and Mobilenet were similar in terms of accuracy, i.e., Resnet-50 Hz (97.3) vs. Mo-bilenet-50 Hz (97.2), Resnet-100 Hz (98.2) vs. Mobilenet-100 Hz (97.9). Here, 50 Hz/100 Hz denotes the down-sampling rate. However, Resnets took more flash memory and longer inference time than did Mobilenets. In conclusion, Mobilenet would be a more efficient model than Resnet to classify arrhythmia in an embedded wearable device.


Subject(s)
Atrial Fibrillation , COVID-19 , Deep Learning , Wearable Electronic Devices , Atrial Fibrillation/diagnosis , COVID-19/diagnosis , Electrocardiography , Humans , SARS-CoV-2 , Signal Processing, Computer-Assisted
19.
Sensors (Basel) ; 22(3)2022 Jan 25.
Article in English | MEDLINE | ID: covidwho-1686940

ABSTRACT

The electrocardiogram (ECG) is considered a fundamental of cardiology. The ECG consists of P, QRS, and T waves. Information provided from the signal based on the intervals and amplitudes of these waves is associated with various heart diseases. The first step in isolating the features of an ECG begins with the accurate detection of the R-peaks in the QRS complex. The database was based on the PTB-XL database, and the signals from Lead I-XII were analyzed. This research focuses on determining the Few-Shot Learning (FSL) applicability for ECG signal proximity-based classification. The study was conducted by training Deep Convolutional Neural Networks to recognize 2, 5, and 20 different heart disease classes. The results of the FSL network were compared with the evaluation score of the neural network performing softmax-based classification. The neural network proposed for this task interprets a set of QRS complexes extracted from ECG signals. The FSL network proved to have higher accuracy in classifying healthy/sick patients ranging from 93.2% to 89.2% than the softmax-based classification network, which achieved 90.5-89.2% accuracy. The proposed network also achieved better results in classifying five different disease classes than softmax-based counterparts with an accuracy of 80.2-77.9% as opposed to 77.1% to 75.1%. In addition, the method of R-peaks labeling and QRS complexes extraction has been implemented. This procedure converts a 12-lead signal into a set of R waves by using the detection algorithms and the k-mean algorithm.


Subject(s)
Electrocardiography , Signal Processing, Computer-Assisted , Algorithms , Arrhythmias, Cardiac , Humans , Neural Networks, Computer
20.
Sensors (Basel) ; 22(2)2022 Jan 17.
Article in English | MEDLINE | ID: covidwho-1634795

ABSTRACT

Remote photoplethysmography (rPPG) is a video-based non-contact heart rate measurement technology. It is a fact that most existing rPPG methods fail to deal with the spatiotemporal features of the video, which is significant for the extraction of the rPPG signal. In this paper, we propose a 3D central difference convolutional network (CDCA-rPPGNet) to measure heart rate, with an attention mechanism to combine spatial and temporal features. First, we crop and stitch the region of interest together through facial landmarks. Next, the high-quality regions of interest are fed to CDCA-rPPGNet based on a central difference convolution, which can enhance the spatiotemporal representation and capture rich relevant time contexts by collecting time difference information. In addition, we integrate the attention module into the neural network, aiming to strengthen the ability of the neural network to extract video channels and spatial features, so as to obtain more accurate rPPG signals. In summary, the three main contributions of this paper are as follows: (1) the proposed network base on central difference convolution could better capture the subtle color changes to recover the rPPG signals; (2) the proposed ROI extraction method provides high-quality input to the network; (3) the attention module is used to strengthen the ability of the network to extract features. Extensive experiments are conducted on two public datasets-the PURE dataset and the UBFC-rPPG dataset. In terms of the experiment results, our proposed method achieves 0.46 MAE (bpm), 0.90 RMSE (bpm) and 0.99 R value of Pearson's correlation coefficient on the PURE dataset, and 0.60 MAE (bpm), 1.38 RMSE (bpm) and 0.99 R value of Pearson's correlation coefficient on the UBFC dataset, which proves the effectiveness of our proposed approach.


Subject(s)
Algorithms , Signal Processing, Computer-Assisted , Face , Heart Rate , Photoplethysmography
SELECTION OF CITATIONS
SEARCH DETAIL